Installation  (for qualified installers only)
27
© Travis Industries
4040830
100-01143
Mantel  Requirements
 
The  combustible  area  above  the  facing  must  not  protrude  more  than  3/4"  from  the  facing.    If  it
does,  it  is  considered  a  mantel  and  must  meet  the  mantel  requirements  listed  below.
 
Use  the  table  below  to  determine  the  maximum  mantel  depth  allowed.    For  example,  if  a  6”
mantel  is  used,  it  must  be  a  minimum  of  6-1/2”  above  the  face.
Maximum Mantel Depth (b)
Mantel 
Height 
Above 
Face (a)
0”
1”
2”
8”
7”
6”
5”
4”
3”
9”
a
b
If you have a tapered mantel, measure the 
mantel height at the point where it 
protrudes 3/4” in front of the face.
0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”
See “Face Dimensions”