Figure 40
The gas line should be
installed by a qualified
service technician.
!
Step 6
The Gas
Supply Line
NOTE: Have the gas supply line installed by a
qualified service technician in accordance with
all building regulations
.
NOTE: Before the first firing of the stove,  the
gas supply line should be purged of any trapped air.
NOTE: Consult local building regulations to
properly size the gas supply line leading to the
(Rp 1/2”) hook-up at the unit.
This gas inlet connection is ISO 7-Rp 1/2 (BSP Rp 1/2).
To install the gas supply line:
• When attaching the pipe, support the control so
that the lines are not bent or torn.
• After the gas line installation is complete, use a
soap solution to carefully check all gas connec-
tions for leaks.
WARNING:
DO NOT USE AN OPEN FLAME TO
CHECK FOR GAS LEAKS
.
• At the gas line access hole, use insulation to
repack the space around the gas pipe.
• Insert insulation from the outside of the fireplace
and pack the insulation tightly to totally seal
between the pipe and the outer casing.
GAS