Monessen Hearth SS38 Manuale Utente

Pagina di 40
5
46D0232
SS38 Direct Vent Gas Stove
PRODUCT FEATURES
PRODUCT SPECIFICATIONS
  This  appliance  has  been  certified  for  use  with  either 
natural or propane gas. See appropriate data plates.
  This appliance is not for use with solid fuels.
  The appliance is approved for bedroom or bedsitting 
room installations.
  The appliance must be installed in accordance with local 
codes if any. If none exist use the current installation 
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in 
Canada.
  This appliance is mobile home approved.
  The appliance must be properly connected to a venting 
system.
  The appliance is not approved for closet or recessed 
installations.
  For alcove installation see “Clearances,” Page 8. 
ON/OFF
PIL
OT
HEA
T
OFF
FAN
ST1099
SS38 controls
Off/Pilot/On
Knob 
Optional Remote 
Receiver 
Door
Figure 1 - 
SS38 Stove Controls
 
Hi/Lo Knob 
On/Off/RS  
Switch 
Blower
ST1099
INSTALLING ABOVE 2000 FEET
  In the USA, the appliance must be derated 4% for every 
1,000 ft. above 2,000 ft elevations.
• 
In Canada, these applications are certified for altitudes 
of 0 - 2,000 ft, and must be derated by 10% for installa-
tions between 2,000 and 4,500 ft. (derate an additional 
4% for every 1,000 ft. above 4,500 ft. elevations.)
GAS PRESSURES
   
Natural 
Propane (LP)
  Inlet Minimum 
4.5” w.c. 
11.0” w.c.
  Inlet Maximum 
10.5” w.c. 
13.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
GAS SPECIFICATIONS & ORIFICE SIZE
 
  
 
Max.Input  Min. Input 
Orifice 
  Model 
Fuel 
BTU/h 
BTU/h 
Size
  SS38NV 
Nat. 
38,000 
27,000 
#32
  SS38PV 
LP 
35,000 
25,000 
#50
The Stratford SS38 is equipped with a variable output 
gas control.