GENERAL INSTALLATION INFORMATION
Figure 3 - 
Typical Installations
ST1100
stove locations
ST1100
STOVE LOCATION
Plan for the installation of your stove. This includes deter-
mining where the unit is to be installed, the vent configura-
tion to be used, framing and finishing details, and whether 
any optional accessories (i.e. wall switch, or remote con-
trol) are desired. Consult your local building code agency 
to ensure compliance with local codes, including permits 
and inspections.
The following factors should be taken into consideration:
  This  stove  should  have  sufficient  access  for  its  safe 
operation and maintenance.
  Locate a position where the flue system of the stove 
can be properly installed without damaging the integrity 
of the building (example: load-bearing  framing mem-
bers).
  When the appliance is installed directly on carpeting, 
tile or other combustible material other than wood floor-
ing, you must set appliance on a metal or wood panel 
extending the full width and depth of the appliance.
  Check stove and flue system clearance requirements.
  Locate the stove where it can be accessed by a gas 
supply line.
  For optimal heat circulation and comfort, centrally locate 
the stove in a large and open room.
  The flow of combustion and ventilation air must not be 
obstructed.
  Minimum clearances to combustibles, side-wall, ceiling, 
woodwork, and windows must be maintained. Page 
8, Figures 4 and 5. 
  This stove may be installed along a wall, across a corner, 
or use an exterior chase. Refer to Figure 3 for suggested 
locations.
  Location should be out of high traffic areas and away 
from  furniture  and  draperies  due  to  heat  from  appli-
ance.
  Never obstruct the front opening of the stove.
  Do  not  install  in  the  vicinity  where  gasoline  or  other 
flammable liquids may be stored.
  Vent  pipe  routing.  See  Venting  section  found  in  this 
manual for allowable venting configurations.
  These units can be installed in a bedroom. See National 
Fuel Gas Code ANSI Z233.1/NFPA 54 (current edition), 
the  Uniform  Mechanical  Code  (current  edition),  and 
Local Building Codes for specific installation require-
ments.