CO-TRK (Analog CO Trunk) 
9
257
50176
Battery reversal detected. This is usually caused by the CO (often seen with 
step-by-step and cross-bar offices in connection with outgoing calls). This is 
detected if the direction of the loop current changes from normal to reverse 
for at least 40 msec. Could occur if the trunk was just installed and for some 
reason the Tip and Ring wires were reversed at the PBX. If battery reversals 
occur during dialing, wrong numbers may result. Refer problem to CO. Ask 
them to remove the battery reversal option.
513
57364
Ground detector stuck active. After several occurrences, an on-board minor 
alarm is generated. Run the short test sequence. If test aborts with Error 
Code 1000, disconnect Tip and Ring and repeat short test. If test still aborts, 
replace circuit pack. If test passes, refer problem to CO. If any other error 
code is received, pursue that problem.
769
57392
CO not releasing after call is dropped from PBX end (TN747B), or the loop is 
not open after a disconnect (TN765). After several occurrences, an 
off-board (TN747B) or on-board (TN465) warning alarm is generated. Refer 
problem to CO.
2561
57345
Single polarity ringing current. This error results from abnormal ringing 
current, but does not prevent the incoming call from being accepted. One 
cause could be that the reverse current detector associated with the port is 
failing. (Will not be detected by any tests.) Another cause could be that 
normal current is not detected. In this case, neither incoming nor outgoing 
calls can be completed, and the dial tone test will also fail. The last cause 
could be that certain types of noise are present on the CO line during the 
silent period of ringing. First check for other errors. If the count for this error 
is very high (255), and all tests pass, then either the reverse current detector 
is defective or the CO line is noisy. If the CO line is suspect, make Tip and 
Ring observations. If the line is determined to be noisy, refer the problem to 
the CO. If the reverse current detector is defective, ignore this error.
2817
57360
Ground but no ringing. This error occurs on an incoming call on a 
ground-start trunk. If ringing is not detected within 5 seconds of the Tip 
being grounded, the call is still accepted. If the CO is of the No. 5ESS. 
switch type, ringing delays of more than 5 seconds during heavy traffic are 
fairly common. Check for other errors.
2817
57393
On the TN465, the loop is opening too slowly after a disconnect. This error 
indicates an on-board problem, although the trunk may be functional. 
Check for other errors.
3073
57376
No loop current on incoming call. The incoming destination has already 
answered and no loop current has been detected. If this is a hard fault, the 
dial tone test and all outgoing calls should also fail. Check for other errors.