Lucent Technologies Release 7 Manuale Utente

Pagina di 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-434
CO-TRK (Analog CO Trunk) 
9
Notes:
a. A demand test of Diagnostic Test (#3) will always return a PASS indication 
for CO-TRK/CO-BD [TN747B] version 8 or greater. However, any errors 
produced as a result of this test will be logged and produce no alarms.
If errors logged by test #3 are the only complaints against this trunk, then 
the system technician should check if MFT/Range Extenders are being 
used. If extenders are present, then there is a good chance that there is 
excessive loop current, which will cause Test #3 to log errors.
However, all else being normal, these errors should not affect the 
customer.
b. The ATMS tests are not part of either test sequence. They are run either on 
demand with test analog-testcall or by the ATMS schedule.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
Table 9-181.
TEST #0 Dial Tone Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be 
busy with a valid call. 
1. Use the command display port UUCSSpp to determine the trunk 
group/member number of the port. Use the status trunk command to 
determine the service state of the port. If the service state indicates that 
the port is in use, then the port is unavailable for certain tests. You must 
wait until the port is idle before retesting.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1001
ABORT
System resources required to run this test were not available. This could be 
due to a failure to seize the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due to 
TDM-BUS errors. 
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page