Lexmark 4039-1XX Manuale Utente

Pagina di 188
56
Service Manual
4039-1XX
Fuser Solenoid
Note:  The fuser solenoid must be mounted on the fuser for this 
adjustment and should be at room temperature.
1. Loosen screw [A].
2. Remove the rubber washer. 
3. Rotate shaft [B] (eccentric) to obtain 4.2 mm ± 0.2 mm 
(0.165 in.± 0.008 in.) air gap.
4. Tighten screw [A].
5. Replace the rubber washer.