AMD 1207 Manuale Utente
![AMD](https://files.manualsbrain.com/attachments/812c0ad06c29fa7e95b1abe2111a1edaa280e91d/common/fit/150/50/1bf990368109a76ea6bd2d8d055ff8d6014a81121adff709966c75a2bfec/brand_logo.png)
Chapter 4
Thermal Design of Custom 1U-2P Systems
21
Thermal Design Guide for Socket F (1207) Processors
32800
Rev. 3.02 3.00
August 2006
Chapter 4
Thermal Design of Custom 1U-2P
Systems
Systems
This chapter describes the motherboard component-height restrictions, thermal-solution design
requirements, sample heat sinks, and attachment methods for custom 1U-2P systems based on socket
F (1207) processors.
requirements, sample heat sinks, and attachment methods for custom 1U-2P systems based on socket
F (1207) processors.
Note: These keep-outs are defined for custom rack mount equipment to optimize thermal and
acoustic performance in these systems. These keep-outs are not compliant with AMD
Processor-In-a-Box (PIB) thermal solutions.
Processor-In-a-Box (PIB) thermal solutions.
4.1
Motherboard Component Height Restrictions
The mounting solution for the heat sink calls for a standard motherboard keep-out region and
mounting holes for the processor. Figure 4 shows an overview of the motherboard component height
restrictions for custom 1U-2P systems based on the thermal solution for socket F (1207) processors.
mounting holes for the processor. Figure 4 shows an overview of the motherboard component height
restrictions for custom 1U-2P systems based on the thermal solution for socket F (1207) processors.
Figure 4.
Motherboard Component Height Restrictions for Custom 1U-2P Systems