Tyco 0-1591700-x Manuale Utente

Pagina di 33
Wireless Access Point  Model 0-1591700-x          User Manual 
Page 30 of 33  
SNMP Trap 
Traps are used by the access point to automatically send alarm information to remote IP 
addresses.  
Item 
This is the same index value as assigned in the SNMP Community on page 29. 
Version 
This pull-down box allows the SNMP version to be assigned. The following options are supported:- 
•  Disable – This disables the SNMP trap generation. 
•  Version 1 – This configures the SNMP trap message to use the SNMP V1 format. 
•  Version 2 – This configures the SNMP trap message to use the SNMP V2 format.  
IP Address 
The individual IP addresses of the receiving stations are specified here. Multiple addresses can be 
configured to ensure that the trap message has a better probability of being received. 
Community 
This is the community string for the SNMP Manager. See page 29. 
 
 
Figure 26 - SNMP Trap Configuration Screen 
Generated Traps 
The access point will automatically generate a trap to signal the cold start condition. This will occur 
if the access point is powered off or a restart is instigated. This trap message is generated about 3 
seconds after the cold start has commenced. This allows the associated IP packet interface to 
power-up and start normal operation. 
 
SNMP MIB Support 
The access point MIB can be interrogated using a standard RFC1213 MIB Browser. This will allow 
the MIB to be browsed and “walked”. A private MIB is not supported.  
 
 
 
 
   
 PL0356                                                     ©2003TycoElectronics                                        Issue 1