Fault-Finding and FAQs 
I cannot communicate with the access point using a direct LAN connection between the PC and 
the access point:- 
1.  Check that a cross-over style Ethernet cable is used between the PC and the access point. 
The cable shipped with the access point should be suitable. A straight-wired cable will not 
work between a PC and the access point. 
2.  Check that the correct IP address of the access point has been entered into the browser. 
The factory default is 192.168.1.1  
3.  Ensure that the IP address of the PC is in the same subnet. The subnet mask should be 
255.255.255.0 
4.  Execute a PING test from the PC to the IP address of the access point. Use the Windows  
system Start > Run and then type the following command:-  
ping 192.168.1.1 –t  
5. Click OK and a new window will open and a scrolling line display showing “Reply from 
192.168.1.1” should be displayed. If the message “Request Timed Out” is displayed then 
there is a problem with the PC settings or the settings of the access point. The steps are:- 
a.  Re-check the PC IP address settings as detailed in page 10. 
b.  Return the access point to the factory default settings, press the reset button on the 
side panel of the access point for at least 3 seconds as described in page 32. 
 
I cannot get the access point to recognise WLAN clients:- 
1. Use 
the 
Wireless > Status menu option to identify the connected clients (see page 28 for 
details). This will list all clients associated with the access point. 
2.  Check the IP address, SSID and channel settings on the client devices to ensure that they 
are correct and that the access point SSID can be seen on the site survey software 
supplied with most wireless client devices.  
3. Check that the client device has WEP encryption temporarily disabled during 
commissioning. 
4.  Ensure that the client device is in the Infrastructure mode and not the Ad Hoc mode. 
5.  Check that there is not another access point system using the same channel and possibly 
the same SSID. The client site survey software tool should indicate other WLAN networks. 
6.  Check that the client has not already associated with another access point operating on 
another channel using the same SSID. This can occur if you add a new access point on a 
different channel to an existing area as client connections with the original access point will 
be retained. This multi-access point issue can be verified by temporarily disabling the 
original access point and checking that the clients “roam” to the new access point.    
7.  Reduce the distance between the client and the access point. 
8.  Check that the DHCP server in the access point is really required for the network. In most 
corporate static applications a centralised DHCP server is used and so the DHCP server in 
the access point should be disabled (see page 19). An incorrect setting of DHCP would 
cause IP address contention and other problems. 
 
 PL0356                                                     ©2003TycoElectronics                                        Issue 1