Agilent Technologies FS2101 Manuale Utente

Pagina di 48
 
The PCI Active Analysis Probe module monitors signals for both 
state and timing analysis.  The below figure displays how the 
cable headers are numbered.   
Signal Connections 
39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9  7 5  3 1 
40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 
 
The following tables list the PCI Active Analysis Probe cable 
headers and the corresponding PCI Local Bus signals after 
these signals have been terminated by the 90K ohm/10pf 
terminators.  
 
Analysis Probe 
Cable Header and 
Pin number 
Logic Analyzer 
channel number 
PCI Signal name 
Header 1 pin 3 
CLK/16 
PCI Clock 
                    5 
no connect 
 
                    7 
15 
FRAME# 
                    9 
14 
IRDY# 
                   11 
13 
TRDY# 
                   13 
12 
STOP# 
                   15 
11 
DEVSEL# 
                   17 
10 
L_CMD3 
                   19 
L_CMD2 
                   21 
L_CMD1 
                   23 
L_CMD0 
                   25 
C/BE3# 
                   27 
C/BE2# 
                   29 
C/BE1# 
                   31  
C/BE0# 
                   33 
RST# 
                   35 
PERR# 
                   37 
INTx# 
 
 
 
 
 
                                                                         38