All 240V spas must be permanently connected (hard 
wired)  to  the  power  supply.  These  instructions  de-
scribe the only acceptable electrical wiring procedure. 
Spas wired in any other way will void your warranty 
and may result in serious injury. See the wiring dia-
gram on page 14.
When  installed  in  the  United  States,  the  electrical 
wiring of this spa must meet the requirements of Na-
tional Electric Code, ANSI/NFPA 70-2008 and any ap-
plicable local, state, and federal codes. The electrical 
circuit  must  be  installed  by  an  electrical  contractor 
and approved by a local building / electrical inspec-
tor.
GFCI and Wiring Requirements
The power supplied to the spa must be on a dedi-
cated  GFCI  protected  circuit  as  required  by  ANSI/
NFPA 70 with no other appliances or lights sharing 
the power.
Use  copper  wire  with  THHN  insulation.  Do  not  use 
aluminum wire.
Use the table below to determine your GFCI and wir-
ing requirements.
Spa Model
GFCI Required
Wires Required
Designer  inground  spas 
with one 5.5 kW heater
One 50 amp GFCI
Four #6 AWG copper wires
Designer  inground  spa 
with two 5.5 kW heaters
Service 1: One 50 amp GFCI
Service 2: One 30 amp GFCI
Service 1: Four #6 AWG copper wires
Service 2: Three #8 AWG copper wires
Wire runs over 85 feet must increase wire gauge to 
the  next  lower  number.  For  example:  A  normal  50 
amp GFCI with four #8 AWG Copper wires run over 
85 feet would require you to go to four #6 AWG cop-
per wires.
Read and follow the heater manufacturer’s safety and 
installation  instructions  prior  to  installation  and  op-
eration. Incorrect installation may damage the heater 
and void its warranty.
Testing the GFCI Breaker
Test the GFCI breaker prior to first use and periodical-
ly when the spa is powered. To test the GFCI breaker 
follow these instructions (spa should be operating):
Press the TEST button on the GFCI. The GFCI will 
1. 
trip and the spa will shut off.
Reset the GFCI breaker by switching the breaker 
2. 
to the full OFF position, wait a moment, then turn 
the breaker back on. The spa should have power 
again.
Electrical Requirements – US and Canada