All 230V spas must be permanently connected (hard 
wired)  to  the  power  supply.  These  instructions  de-
scribe the only acceptable electrical wiring procedure. 
Spas wired in any other way will void your warranty 
and may result in serious injury.
This the only acceptable electrical wiring procedure. 
Spas wired in any other way will void your warranty. 
See the wiring diagram on page 16.
The  electrical  wiring  of  this  spa  must  meet  the  re-
quirements of any applicable local, state, and federal 
codes. The electrical circuit must be installed by an 
electrical contractor and approved by a local building 
/ electrical inspector.
RCD and Wiring Requirements
The power supplied to the spa must be on a dedi-
cated RCD protected circuit with no other appliances 
or lights sharing the power.
Use  copper  wire  with  THHN  insulation.  Do  not  use 
aluminum wire.
Use the table below to determine your GFCI and wir-
ing requirements.
Wire runs over 85 feet must increase wire gauge to 
the  next  lower  number.  For  example:  A  normal  50 
amp RCD with four #8 AWG copper wires run over 
85 feet would require you to go to four #6 AWG cop-
per wires.
Testing the RCD Breaker
Test the RCD breaker prior to first use and periodical-
ly when the spa is powered. To test the RCD breaker 
follow these instructions (spa should be operating):
Press the TEST button on the RCD. The RCD will 
1. 
trip and the spa will shut off.
Reset the RCD breaker by switching the breaker 
2. 
to the full OFF position, wait a moment, then turn 
the breaker back on. The spa should have power 
again.
Electrical Installation --  Europe
Spa Model
GFCI Required
Wires Required
Designer inground spas with one 3 
kW heater
One 32 amp RCD or two 16 amp 
RCDs
Four #10 AWG copper wires
Designer  inground  spa  with  one  3 
kW heater and one 5.5 kW heater
Service  1:  One  32  amp  RCD  or 
two 16 amp RCDs
Service  2:  One  32  amp  RCD  or 
two 16 amp RCDs
Service 1: Four #10 AWG copper 
wires
Service 2: Three #10 AWG copper 
wires