Remote Equipment Topside Control 
Panel
The next few steps to complete the installation should 
be performed along with installation of the tempera-
ture sensor and 12V spa light wiring (if applicable). All 
of these components are generally installed using the 
same conduit. 
Locate  the  topside  control panel extension  loom 
1. 
in  the  control  box  mounted  with  the  equipment 
pack. This extension loom and attached black ter-
minal connector (see figure at right) will be used 
to connect the topside control panel to the control 
box.
Connect one end of the black terminal connector 
2. 
to the topside control panel cable.
Connect the other end of the terminal connector 
3. 
to the extension loom.
NOTE: This connection must be kept dry. We recom-
mend that a waterproof junction box be used in instal-
lations where moisture could penetrate this terminal 
connector. 
Lay out the extension loom to verify that you have 
4. 
enough length to reach the control box. Remem-
ber that conduit runs are not generally run in a 
straight  line.  Every  bend,  and  up  and  down  run 
consumes line length. Take this into consideration 
when verifying electrical and plumbing runs.
Electrical and Electronic Connection
Connect the extension loom to the control panel 
5. 
location  on  the  circuit  board  located  inside  the 
control  box.  You  will  also  need  to  connect  both 
the temperature and high limit sensors to the cir-
cuit board prior to testing. (See the temperature 
and high limit installation instruction on the next 
page for proper identification and see the wiring 
diagram on the inside cover of the control box for 
proper placement.) 
Turn on the power supply to the spa equipment 
6. 
and briefly test all functions on the topside control 
panel to verify that both connections and exten-
sion loom are in working order before proceeding 
with the installation.
NOTE: Circuit board programming will not allow spa 
operation  without  both  the  temperature  and  high 
limit sensors being properly connected to the circuit 
board.
Once topside panel operation is verified. Turn off 
7. 
power,  disconnect  the  extension  loom  from  the 
circuit board and GENTLY route through conduit 
to complete installation.
NOTE: This loom and its connector are not meant to 
withstand heavy pulling. Make sure, when routing the 
extension loom and temperature sensor lines through 
conduit, you exercise extreme caution.
Once properly run through the conduit, repeat steps 
5 and 6 above.