Cleveland Range 24-CDP-10 Dépliant

Pagina di 2
UTILITY CONNECTIONS
ELECTRIC
115V - 1 Phase
Controls - 51 Watts
(NOT TO SCALE)
SECT.
IV
PAGE 
22
0707
Litho in U.S.A.
DIRECT STEAM
COLD WATER
DRAINAGE
C
D
35 psi minimum
60 psi maximum
3
4
˝ Dia. NPT for
Condenser
1
1
2
˝ Dia.
Do not connect other units
to this drain.
Drain must not be located
beneath the steamer itself.
No PVC pipe for drain.
Steam supply:
Furnish 
3
4
˝ IPS minimum line.
20 to 50 psi minimum required.
For pressures between 50 to 120 psi, on additional
Pressure Reducing Valve must be specified.
C
10 — 12˝ x 20˝ x 2
1
2
˝ Cafeteria Pans or
20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
2
6 — 12˝ x 20˝ x 4˝ Cafeteria Pans
TOTAL CAPACITY 
(2 Compartments)
Electrical Supply
Drain: 1.50˝ Dia.
Water Supply for Condenser 
3
8
˝ Dia. NPT
Steam Supply: 0.75˝ Dia.
A
B
C
D
Each Compartment has 
capacity for:
• Five, 12˝ x 20˝ x 2
1
2
˝ deep
Cafeteria Pans.
WATER QUALITY 
REQUIREMENTS
The quality of water varies
greatly from region to region.
Steam equipment generators
must be drained daily and
chemically descaled periodically
to ensure proper operation. To
minimize service problems
caused by the accumulation of
minerals and chemicals in water
review the following quality
guidelines with a local water
treatment specialist. Inlet water
that is beyond these specified
guidelines should be treated to
achieve these acceptable limits.
Total Dissolved Solids less than
60 ppm, Alkalinity less than 20
ppm, Silica less than 13 ppm,
pH factor greater than 7.5,
Chlorine less than 30 ppm.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC and UL/NSF#4.
CLEARANCE
Right - 3”, Left - 3”, Rear - 3” 
(12” on control side if
adjoining wall or 
equipment is over 30” 
high for service access)
Contact factory for 
variances to clearances.