Cisco Headend Digital Broadband Delivery System

Pagina di 68
 
 
Setting Up the DNCS to Support the HDD Test 
4011411 Rev B 
51 
 
6  Finish setting up the BFS to support the HDD Test by placing the HDD 
Performance Specification file on the HDD Test server. Go to Placing the HDD 
Performance Specification File on the HDD Test Server (on page 51). 
 
Placing the HDD Performance Specification File on the HDD Test Server 
Note: This procedure can be used for systems that support multiple or single sites. 
1  In the Broadcast File Server List window, double-click the hddtest server. The 
hddtest server opens to show its contents. 
2  Click File and select New File. The Set Up File window opens. 
3  Follow these instructions to enter data into the fields of the Set Up File window: 
 
Click in the File Name field and type testparam.cfg.  
 
Click the Source Name arrow and select Out of Band.  
 
Click in the File Path field and type /dvs/resapp/Tools/testparam.cfg
Result: The Set Up File window is configured as shown in the following 
example.  
 
4  Click Save to save your changes and close the Set Up File window. The HDD 
Performance Specification file is placed on the HDD Test server. As a result, the 
testparam.cfg file appears beneath the open hddtest server. 
5  Click File and select Close to close the Broadcast File Serve List window. You 
have successfully set up the BFS to support the HDD Test. 
6  Go to 
Verify That the HDD Test Server Is Successfully Set Up (on page 48) t
verify that the BFS supports the HDD test.