If the OMM does not find a ConfigURL during initial setup, the OMM contacts the RCS to request a 
ConfigURL, using its RFP MAC address. If the RFP MAC Address is configured in the RCS, the RCS 
provides a ConfigURL that points to an external provisioning server. The OMM attempts to load all 
configuration and resource files from the ConfigURL received from RCS. 
 
Note:  The SIP-DECT OMM only uses the ConfigURL from RCS. Other 
information provided from RCS is not supported.  
The OMM requests information from RCS only if no information has been retrieved from RCS prior to the 
request. The response is stored permanently in the OMM. To force a new RCS request, the OMM must 
be reset to default settings, through the 
Discard OMM DB and configuration files or Reset OMM 
RFP(s) to factory defaults on restart (see section 5.4.1.15). 
 
7.8.9  CUSTOMER LOGO ON OMM WEB SERVICE  
SIP-DECT 6.0 and later supports the integration of a customer-specific logo on the OMM Web service 
interface. If a customer_image.png file is available on an external file server, customers can integrate 
their own logo into the OMM. This logo is displayed beside the Mitel logo on the top bar. 
This image can be imported by: 
• 
 configuration of a branding image URL to a file server using OMP (see section 6.5.2.7) 
• 
automatic search for a file named ‘customer_image.png’ on the provisioning server 
The branding image is stored permanently in the OMM database, ensuring that the image is available 
even if a configured file server or provisioning server is not reachable. The file is deleted automatically 
from the server on a “file not found” response or by disabling the branding image URL configuration. 
The picture should not be larger than 50 pixels high and 216 pixels wide. 
 
Service Provider 
SIP-DECT 
RCS 
1.  Registration of 
RFP’s MAC 
address or 
SIP-DECT 
System’s PARK 
2.  OMM inquiry upon start-up 
3.  Re-direction to Configuration Server 
4.  SIP-DECT OMM 