7. 3 
The shutter speed can be set by the horizontal scanning period (1H) or by the number of frames.
Setting by 1H
( 1 ) 
1H/796H ~ 795H/796H stands for the setting by the 1H and the shutter speed can be set by the 1H (43.05 µs).
When operating Partial Scanning or binning, the number’s listed below can be used for setting.
Partial scanning OFF 
Partial scanning 40fps, E.40fps 
Partial scanning 42fps, E.42fps 
Partial scanning 50fps, E.50fps 
Partial scanning 60fps, E.60fps 
Partial scanning 70fps, E.70fps 
Partial scanning 80fps, E.80fps 
Partial scanning 90fps, E.90fps 
1H/796H ~ 795H/796H
1H/580H ~ 579H/580H 
1H/553H ~ 552H/553H 
1H/465H ~ 464H/465H 
1H/387H ~ 386H/387H 
1H/332H ~ 331H/332H 
1H/290H ~ 289H/290H 
1H/258H ~ 257H/258H
Setting by the frame
( 2 ) 
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.
(4FRM setting)
n+1
n
RGB data
(video interval image)
(Internal VD) 
FVAL