5.  Configuration 
The mAI085-MB Actuator Interface is configured using a menu driven interface.  The operator 
keyboard changes function during configuration.  This section will describe the configuration of 
the interface.  The description will first define the keyboard functions, then describe the 
configuration menus used. 
5.1  Overview of System Configuration  
Each actuator connected to the Interface has parameters that control its operation.  These 
parameters are stored in non-volatile memory at each actuator.  These parameters can be 
modified using the keyboard of the Interface.  The Interface can also store in its internal non-
volatile memory, a copy of the parameters from each actuator. 
The following table defines the steps used to set the actuator parameters and calibrate each 
actuator controller. 
 
Step  Function 
Action at Interface 
Action at 
Actuator Controller 
Load Factory Default Values for the 
Interface using the Factory Values 
Menu
.. 
All internal Interface 
parameters are 
overwritten with the 
factory default values 
no action 
Using the Controller Menu, set the iD 
and adjust the parameters as required 
for controller 1. 
Parameters for 
actuator controller 1 
are adjusted in the 
Interface parameter 
table 
no action 
Using the Controller MenuSnd the 
adjusted parameters to controller 1. 
no action 
Parameters at 
actuator controller 1 
are overwritten with 
values from the 
Interface 
From the Controller Menu, calibrate 
controller 1, using the CAL function. 
no action 
Calibration 
parameters are 
adjusted by the 
actuator controller 
Test the configuration by exercising 
controller 1 
Open and close the 
gate to several 
positions including fully 
open and fully closed 
and verify the limit 
switch operation if 
used 
Controller will position 
the gate