High End Systems High End LCD Controller for Studio Color Manuale Utente

Pagina di 272
2-16
Connecting Fixtures
Studio Color LCD Controller
Terminators
The last device on each link must have a 120 ohm, 1/4 watt 
(minimum) terminator attached to its Data Out connector.  
You can construct terminators by following the instructions 
in Figure 2-11:
Figure 2-11.  Constructing a data cable terminator.
Connection Rules
Before continuing, you need to understand the following  
rules:
Each controller supports up to 8 unique fixtures.  If you 
want to connect more than 8 fixtures to a controller, some 
of the fixtures will have to share the same fixture 
number, and will thus respond to the same set of control 
commands.
Note
The Studio Color fixture has several built-in random 
(or unsynchronized) effects which work randomly 
even if multiple fixtures are assigned the same fixture 
number.  For more information, see the section titled 
“Programming Hints” on page 3-2.  
You can expand your system beyond 8 independently-
operating fixtures by connecting master and slave 
controllers together.
12
0
Ω
 
1.  Obtain a male XLR connector.
2.  Disassemble the connector.
3.  Solder a 120 ohm resistor, minimum
     of 1/4 watt, between pins 2 and 3.
4.  Reassemble the connector.
5.  Install the terminator in the Data Out
     port of the last device in the link.