High End Systems High End LCD Controller for Studio Color Manuale Utente

Pagina di 272
Studio Color LCD Controller
Connecting Fixtures
2-17
2
A serial data distributor must be used if either of the 
following is true:
You wish to connect more than 32 fixtures to a 
controller or more than 32 master/slave controllers 
together.  
The end-to-end cable span (the total length of all 
cables) on any link exceeds 500 ft. (153 m).
The serial data distributor regenerates and retimes the signal; 
failure to use it can result in data errors.
Examples
Example #1:  One controller is connected to 8 fixtures, each 
of which will respond independently to control commands.
Figure 2-12.  Each of the eight fixtures connected to 
this controller responds independently to control 
commands.
The example above shows one Studio Color LCD controller 
connected to 8 Studio Color fixtures.  Each fixture is 
numbered 1 through 8 using the fixture’s menus (see 
“Configuring the Fixtures” on page 2-9).  A terminator must 
be attached to the Data Out connector of the last Studio Color 
fixture in the link (see “Terminators” on page 2-16).
XLR data cabling
8 independently-functioning fixtures, 
8 unique addresses
Fixture #1
Fixture #2
Fixture #3
Fixture #4
Fixture #5
Fixture #6
Fixture #7
Fixture #8
Terminator
Stu
dio
 Co
lor
Stu
dio
 Co
lor
Stu
dio
 Co
lor
Stu
dio
 Co
lor
Stu
dio
 Co
lor
Stu
dio
 Co
lor
Stu
dio
 Co
lor
Stu
dio
 Co
lor