Studio Color LCD Controller
Rack Mounting the Controller 2-25
2
Rack Mounting the Controller
After configuring the controller and connecting cables as 
described earlier in this chapter, you can mount the Studio 
Color LCD controller in a standard 19-inch rack as described 
in this section.
The Studio Color LCD controller is designed to mount into a 
standard 19-inch equipment rack as specified by the MIL-
STD-189 and ANSI/EIA RS-310-C-77 specifications.  The 
unit occupies four standard rack spaces.
1.
Insert the unit into the front of the equipment rack. There 
must be at least 7 inches of available rack space.  Be sure to 
feed the power cord in first, being careful not to pinch or 
otherwise damage the power cord.  Do not use the unit if the 
power cord is damaged.
2.
Attach the unit to the equipment rack by placing mounting 
screws through the two mounting holes behind the handles on 
each side of the controller.  Attach the unit by the lower two 
mounting holes first as this is where the majority of weight is 
supported.  Finish by attaching the unit through the remaining 
two holes.
3.
The primary disconnect on this device is the power cord.  The 
cord should be accessible or be placed into a power strip with 
an accessible on/off switch.