After injectors replacement adjust the burner flame 
(see Low Flame Adjustment paragraph). 
Check the appearance of each burner’s flame at HI- 
LO settings, if the flame appear too large or too small 
make sure that all steps were completed correctly. 
Convert the pressure regulator on LP position fol-
lowing the illustration 20. 
Converting Appliances for Use with NG 
Gas  
If this appliance should be converted for use with gas 
NG (natural gas), each of the following modifications 
must be performed. 
1.  Replace all injectors following the step described 
on page 18, observe the number stamped on the 
side, this number codes the orifice diameter and 
its correct burner location (following the illustration 
of injectors position). 
2.  Convert the pressure regulator on LP position (fol-
lowing the illustration of pressure regulator con-
version). 
3.  Adjust the burner flame (see Low Flame Adjust-
ment paragraph). 
Check the appearance of each burner’s flame at HI- 
LO settings, if the flame appears too large or too small 
make sure that all steps were completed correctly. 
Pressure regulator conversion 
The appliances is designed for use with NG gas or LP 
gas. The gas pressure regulator is supplied. It must 
be installed in the gas way ahead of manifold en-
trance. It is pre-set for use with the gas supplied with 
the appliances. For use with different gas must be 
converted. 
For the pressure regulator conversion following 
the below instructions: 

Disconnect all electrical power, at the main circuit 
breaker or fuse box. 

Shut off the gas supply to the cooktop by closing 
the manual shut-off valve. 

Adjust the pressure regulator, by following the in-
struction (see figure) 
1.  Unscrew the regulator cap 
2.  Unscrew the plastic conversion plug from the cap 
turn over and screw back (wide section away from 
cap for LP and against cap for NG) see figures 
below. 
3.  Replace the cap regulator. 
 
 
 
              Before replace the regulator cap. 
              Check the position of plug. 
              Suitable for the gas converted. 
 
Figure 20.  Pressure regulator conversion