4. SYSTEM STARTUP 
 
4.5.3 System option 2 setting 
Set control mode (standard mode or interface mode) by System option 2 (parameter No.0002). 
When using interface mode, select "1: Interface mode". 
When interface mode is assigned and system is startup, the in interface mode signal (IFMO) turns ON. 
Control mode setting is imported during system startup (system command code: 000Ah), and cannot be 
changed during system running (system status code: 000Ah). 
 
(1) System parameter 
 
Parameter 
No. 
Abbreviation Name  Initial 
value Units
Setting 
range 
Function 
0002 *SYSOP2 
System 
option 2 
0000h  
0000h 
to 
1101h 
Axis No. assignment
Set 1 when validating axis No.
assignment. When axis No.
assignment is invalid, axis No. is
automatically assigned.
0: Invalid
1: Valid
0
Control mode selection
Set the control mode.
0: Standard mode
1: Interface mode
Consistency check selection at
system startup
Set whether to perform consistency
check for controlled axes setting at
system startup.
0: Valid
1: Invalid