LYNXR-I Installation and Setup Guide
 
 
- 10 -
 
LRR/IP Communications Device 24-Hour Standby Power 
If you are installing the AlarmNet 7845GSM/7845i-GSM or 7845i-L you must install the Super High Capacity battery 
P/N WALYNX-RCHB-SHA in the LYNXR-I.  
!
 
The 7845i-ENT/7845i and 7845CV2 can not be used for installations requiring 24-hour standby. 
 
AlarmNet 7845CV2  
1.  Connect the 4-wire communications cable to the LRR/IP communications port on the LYNXR-I. 
2.  Connect the four wires to the 7845CV2 as shown below: 
 
LRR/IP COMMUNICATIONS PORT
07000-011-V2
7845CV2
TB1
V+
GND
Z1/DATA IN 
RAD FLT/ DATA OUT
P1 BAT
LYNXR-I CONTROL PANEL
RED
NC
BLK
GRN
YEL
RED
BLK
GRN
YEL
+12 VDC
GND
D
ATA
 I
N
D
A
T
A
 OUT
4-WIRE CABLE (N4632-4)
LYNX
STANDARD
CAPACITY
BATTERY
BATTERY
ADEMCO
K4362
 
Connecting AlarmNet 7845CV2  
 
Configuring Long Range Radio and Internet Communication Devices 
1.  Enable the communications device in programming field *55 and configure alarm reporting and module supervision in 
programming field *77. 
2.  Program the device as required using the 7720P programmer (refer to the Installation Instruction for the device that you 
are installing for additional information). Note that the device address must be set to 3. 
 
1.  When programming an AlarmNet 7845CV2 the radio’s “current limit” most option must be set 
to [Y] (yes). 
2.  The device must be registered before downloading or alarm reporting can take place.