• Electrical Connection 
A 15 amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. 
Preferably, the fireplace will be on a dedicated circuit as other appliances on the 
same circuit may cause the circuit breaker to trip or the fuse to blow when the heat-
er is in operation. The unit comes standard with a 6 ft. (1.8 m) long three wire cord, 
exiting the right side of the fireplace. Plan the installation to avoid the use of an 
extension cord. 
Extension cords are for temporary use only. If an extension cord must be 
used, it must be UL/CSA certified, rated at 15A (1875W), 125V maximum with 14 AWG mini-
mum and constructed of two current carrying conductors with ground. A heavy duty extension 
cord with the shortest length possible for the connection is recommended and must not be 
longer than 50 ft. (15.2 m). Do not coil or cover the extension cord.
Electrical outlet wiring must comply with local building codes and 
other applicable regulations to reduce the risk of fire, electrical shock 
and injury to persons.
Do not use this fireplace if any part of it has been under water. 
Immediately call a qualified service technician to inspect the fireplace 
and replace any part of the electrical system which has been under 
water.
• Grounding Instructions
This heater is for use on 120 volts. The cord has a plug as shown at A in Figure 1. 
An adapter as shown at C is available for connecting three-blade grounding-type 
plugs to two-slot receptacles. The green grounding lug extending from the adapter 
must be connected to a permanent ground such as a properly grounded outlet box. 
The adapter should not be used if a three-slot grounded receptacle is available.
A
B
C
Figure 1
Grounding Means
Cover of 
Grounded 
Outlet Box
Metal Screw
Grounding Pin
Adapter