• Direct (Hard) Wiring Electric Fireplace
This instruction is intended as a guide for replacing the power cord supplied with 
Models EF22/26/33/36 electric fireplace with direct (hard) wiring.
NOTE: When direct wiring this appliance, it must be connected to a 15 Amp 
dedicated circuit breaker or fuse in the electrical panel of the dwelling. The cable 
between the circuit/fuse panel and the fireplace must meet all local and national 
codes, and in no case shall the wires be less than 14 gauge.
1.  Make sure the power to the unit has been turned off, the power cord is 
unplugged from the wall outlet and the unit has cooled down if it has been oper-
ating.
2.  Follow Steps 3 through 6 in “Replacing Light Bulbs” section, Page 8, to gain 
access to control panel behind the touchpad controls.
3.  Locate where the power cord enters the control compartment on the right hand 
side of the unit. Using wire cutters, cut the power cord within three inches (75 
mm) of the point where it exits the cabinet.
4.  Carefully separate the three (3) wires of the power cord into separate wires 
by gently pulling them apart. DO NOT use a knife, as this may expose bare 
conductor. The hot wire is connected on the  right hand side and is terminated 
with a  90° terminal (marked as “power” on the control board). The neutral wire 
is connected on the left hand side and is terminated with a straight terminal 
marked as “Neutral” on the control board. The green ground wire is attached to 
a ground stud.
5.  Using wire strippers, strip approximately 5/8" (15 mm) from the ends of the hot 
and neutral wires.
6.  Using a wrench, remove the #10-24 hex nut from the ground stud where the 
green wire from the power cord is attached. Remove and discard the green 
wire. Reinstall the nut but do not tighten yet.
7.  While standing on the right side of the unit, locate the power cord where it exits 
the cabinet. Using pliers, gently cut and remove the power cord. Dispose of the 
power cord.
8.  Using a slotted screwdriver, remove the 7/8" (22 mm) diameter knockout from 
the right hand side of the cabinet above where the strain relief was located.
9.  Route the electrical cable from the breaker/fuse panel through the 7/8" (22mm) 
diameter hole and secure to the cabinet using an approved clamp. The power 
wires should extend approximately 6" (152mm) into the control compartment.
10.  Connect the ground wire from the power cable by wrapping it around the 
ground stud of the unit and securing it using the #6-32 nut.
11.  Using a wire nut, connect the hot lead (black), of the power cable to the power 
cord wire that ends in 90° terminal (on the control board side, it ends on your 
right hand side). Similarly, connect the neutral wire (white), of the power cable 
to the power cord ending with the straight terminal (on the control board side, it 
ends on your left hand side) using a wire nut. It is recommended that the wire 
nuts be taped to the wires, using electrical tape, as an extra safety measure.
12.  Visually check that none of the wires in the control compartment have been dis-
lodged from the controls. If they have, use the wiring diagram on the unit or in 
the instruction manual to replace them in their proper location.
13.  Turn the power to the unit on at the breaker/fuse panel. Place the unit into oper-
ation and check to make sure that all of the systems are working properly.
WA R N I N G : T h i s 
procedure 
must 
be  conducted  by  a 
qualified electrician, in accor-
dance  with  National  and 
local  codes.  In  the  U.S.A., 
the installation must conform 
to  the  National  Electrical 
Code,  ANSI/NFPA  No.  70. 
In  Canada,  the  installation 
must  conform  to  the  cur-
rent  CSA  C22.1  Canadian 
Electrical Code.
WARNING:  Make 
sure  the  power  to 
the  unit  is  off,  and 
the power cord is unplugged 
from  the  wall  outlet  before 
proceeding with this conver-
sion.  Failure  to  do  so  may 
result  in  property  damage, 
personal  injury  or  loss  of 
life.
WARNING:  Make 
sure  the  power  to 
the  power  cable 
has  been  turned  off  at  the 
breaker/fuse  panel  of  the 
residence  before  proceed-
ing.