page 12 — cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) 
cOMpOnents
Figure 3. Submersible Pump Components
Figure 3 shows the location of the basic components, for 
the CX400/PX400 submersible pumps. Listed below is a 
brief explanation of each component
1. 
AC Power Cable – This unit is supplied with a 19 ft. 
(approximately 6 m) AC power cable with a grounding-
type plug. Always check the cable for signs of wear. 
never use a defective power cable.
2. 
carrying Handle – Always carry the submersible pump 
by its handle. 
never! carry the pump by its power 
cord. Carrying or lifting the pump by the power cord 
will cause undue stress on the cord and can ultimately 
dislodge the cord from the pump.
3. 
thermal  overload  protection  – This  pump  is 
equipped with a thermal overload protection device 
that  will  shut  down  the  motor  in  the  event  of  high 
operating temperatures. The motor will automatically 
restart once the temperature returns to an acceptable 
operating temperature.
4. 
Mechanical Seal  – The hydraulic oil in the pump cavity 
is designed to provide cooling for the pump seal. This 
SUBMERSIBLE
PUMP
1
2
6
3
8
7
4
5
allows the pump to run dry for a limited period of time
5. 
discharge port – Connect a 2-inch hose to this port. 
Remember to adequately support the discharge hose 
to avoid stress on the pump.
6. 
mechanical Seal oil plug – Remove this plug to check 
and add lubrication oil (Paraffin P70 lubricant) to the oil 
cavity. This oil protects the mechanical seal. Oil cavity 
should be full enough to cover seal spring.
7. 
volute/impeller  –  Impellers  are  constructed  of 
abrasion-resistant  plastic  to  minimizes  wear  and 
prolong service life.
8. 
Electric Motor – These submersible pumps utilize a 
60 Hz, single-phase, 115 VAC, 1/2 HP electric motor. 
Consult with a licensed electrician before connecting 
motor to a power source and control boxes. Observe 
all city and local safety codes.