page 14 — cx400/px400 Sub. pump • operation and partS manual — rev. #1 (12/03/10) 
flOat switches
mechanical Float Switch
Mechanically activated float switches offer a reliable low 
current control for dewatering applications.
How it Works
The mechanical float switch control will turn ON (close) 
when the float tips 45° above -horizontal, indicating a high 
level, and turns OFF (opens) when the float switch drops 
45° below horizontal. Reference Figure 6 and Figure 7. 
Maximum pumping range is 120 degrees. See Figure 5 
below.
Figure 5. Pumping Range (Float Switch)
pumping range
The pumping range of the pump is determined by the float 
switch tether cord. Use Table 3 as guide line to determine 
your required pumping range. Pumping ranges are based 
on non-turbulent conditions. Range may vary due to water 
temperature and cord shape. Please note as the tether 
length  increases,  so  does  the  variance  of  the  pumping 
range.
PUMP
ON
60
60
120
PUMP
OFF
SUBMERSIBLE
PUMP
table 3. pumping range
tether length
2 in.
5.08 cm.
4 in.
10.16 cm.
6 in.
15.24 cm.
8 in.
20.32 cm.
10 in.
25.4 cm.
12 in.
30.48 cm.
14 in.
35.56 cm.
16 in.
40.46 cm.
pumping range
6 in.
15.24 cm.
10 in.
25.4 cm.
14 in.
35.56 cm.
18 in.
45.72 cm.
22 in.
55.88 cm.
27 in.
68.58 cm.
31 in.
78.74 cm.
35 in.
88.9 cm.
design Features
Float  switch  housings  are  constructed  of  high-impact, 
corrosion  resistant  polypropylene  with  mechanically 
activated, snap action contacts.
 
„
Suitable for most liquid environments.
 
„
Hermetically sealed.
 
„
Thick-walled non-corrosive PVC plastic enclosure.
 
„
Pressure tested to 30 ft. (9 meters).
 
„
Standard SJO, 16-gauge, 2 conductor cord (20 ft./6.09 m).
Figure 6. Float Switch (Closed)
Figure 7. Float Switch (Open)
ON/OFF
RAMP
STEEL
BALL
CONTACTS
CLOSED
ON/OFF
RAMP
STEEL
BALL
CONTACTS
OPEN