Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
4 -  35 
4. OPERATION 
 
4.4.7 Dog type rear end reference home position return 
POINT 
 
This home position return method depends on the timing of reading 
Proximity dog (DOG) that has detected the rear end of a proximity dog. 
Hence, if a home position return is made at the creep speed of 100r/min, an 
error of  200 pulses will occur in the home position. The error of the home 
position is larger as the creep speed is higher. 
 
The position where the axis, which had started decelerating at the front end of a proximity dog, has 
moved the after-proximity dog moving distance and home position shift distance after it passed the rear 
end is defined as a home position. A home position return that does not depend on the Z-phase signal can 
be made. 
 
(1) Signals, parameters 
Set the input signals and parameters as indicated below. 
Item Device/Parameter 
used 
Description 
Automatic/manual selection (MD0)  Short (turn on) MD0-SG. 
Point table No. selection 1 (DI0) 
Open (turn off) DI0-SG. 
Manual home position return mode 
selection 
Point table No. selection 2 (DI1) 
Open (turn off) DI1-SG. 
Dog type rear end reference home 
position return 
Parameter No.8 
5: Select the dog type rear end reference. 
Home position return direction 
Parameter No.8 
Refer to section 4.4.1 (2) and select the home position return direction. 
Dog input polarity 
Parameter No.8 
Refer to section 4.4.1 (2) and select the dog input polarity. 
Home position return speed 
Parameter No.9 
Set the speed till the dog is detected. 
Creep speed 
Parameter No.10 
Set the speed after the dog is detected. 
Home position shift distance 
Parameter No.11 
Set when the home position is moved from where the axis has passed 
the proximity dog rear end. 
Moving distance after proximity dog  Parameter No.43 
Set the moving distance after the axis has passed the proximity dog 
rear end. 
Home position return acceleration/ 
deceleration time constants 
Point table No.1 
Use the acceleration/deceleration time constant of point table No. 1. 
Home position return position data 
Parameter No.42 
Use to set the current position on completion of home position return. 
 
(2) Timing chart 
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Automatic/manual
selection (MD0)
Movement finish (MEND)
Rough match (CPO)
Home position return
completion (ZP)
Servo motor speed
Proximity dog (DOG)
Forward rotation start (ST1)
Home position return speed
Creep speed
Moving distance after proximity dog
Home position shift distance
Proximity dog
5ms or more
3ms or less
Home position address
Parameter No. 42
Reverse rotation start (ST2)
ON
OFF
 
The parameter No.42 (home position return position data) setting value is the positioning address 
after the home position return is completed.