Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
4 -  36 
4. OPERATION 
 
4.4.8 Count type front end reference home position return 
POINT 
 
This home position return method depends on the timing of reading 
Proximity dog (DOG) that has detected the front end of a proximity dog. 
Hence, if a home position return is made at the home position return speed 
of 100r/min, an error of  200 pulses will occur in the home position. The 
error of the home position is larger as the home position return speed is 
higher. 
 
The position where the axis, which had started decelerating at the front end of a proximity dog, has 
moved the after-proximity dog moving distance and home position shift distance is defined as a home 
position. A home position return that does not depend on the Z-phase signal can be made. The home 
position may change if the home position return speed varies. 
 
(1) Signals, parameters 
Set the input signals and parameters as indicated below. 
Item Device/Parameter 
used 
Description 
Automatic/manual selection (MD0)  Short (turn on) MD0-SG. 
Point table No. selection 1 (DI0) 
Open (turn off) DI0-SG. 
Manual home position return mode 
selection 
Point table No. selection 2 (DI1) 
Open (turn off) DI1-SG. 
Count type dog front end reference 
home position return 
Parameter No.8 
6: Select the count type dog front end reference. 
Home position return direction 
Parameter No.8 
Refer to section 4.4.1 (2) and select the home position return 
direction. 
Dog input polarity 
Parameter No.8 
Refer to section 4.4.1 (2) and select the dog input polarity. 
Home position return speed 
Parameter No.9 
Set the speed till the dog is detected. 
Creep speed 
Parameter No.10 
Set the speed after the dog is detected. 
Home position shift distance 
Parameter No.11 
Set when the home position is moved from where the axis has passed 
the proximity dog rear end. 
Moving distance after proximity dog 
Parameter No.43 
Set the moving distance after the axis has passed the proximity dog 
rear end. 
Home position return acceleration/ 
deceleration time constants 
Point table No.1 
Use the acceleration/deceleration time constant of point table No. 1. 
Home position return position data 
Parameter No.42 
Use to set the current position on completion of home position return. 
 
(2) Timing chart 
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Movement finish (MEND)
Rough match (CPO)
Home position return
completion (ZP)
Servo motor speed
Proximity dog (DOG)
Forward rotation
start (ST1)
5ms or more
3ms or less
Proximity dog (DOG)
Creep speed
Moving distance after proximity dog
Home position shift distance
Home position return speed
Automatic/manual
selection (MD0)
Home position address
Parameter No. 42
Reverse rotation 
start (ST2)
ON
OFF
 
The parameter No.42 (home position return position data) setting value is the positioning address 
after the home position return is completed.