Mitsubishi Electronics MR-J2S- CP ユーザーズマニュアル

ページ / 357
 
 
14 -  36 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.2.2 Circuit breakers, fuses, magnetic contactors 
Always use one circuit breaker and one magnetic contactor with one servo amplifier. When using a fuse 
instead of the circuit breaker, use the one having the specifications given in this section. 
Fuse 
Servo amplifier 
Circuit breaker 
Class
Current [A]  Voltage [V] 
Magnetic contactor 
MR-J2S-10CP(1) 30 
frame 
5A 
K5 
10 
MR-J2S-20CP 30 
frame 
5A 
K5 
10 
MR-J2S-40CP 20CP1 
30 frame 10A 
K5 
15 
MR-J2S-60CP 40CP1 
30 frame 15A 
K5 
20 
MR-J2S-70CP 
30 frame 15A 
K5 
20 
MR-J2S-100CP 
30 frame 15A 
K5 
25 
S-N10 
MR-J2S-200CP 
30 frame 20A 
K5 
40 
S-N18 
MR-J2S-350CP 
30 frame 30A 
K5 
70 
S-N20 
MR-J2S-500CP 
50 frame 50A 
K5 
125 
S-N35 
MR-J2S-700CP 100 
frame 
75A 
K5 
150 
250AC 
S-N50 
 
14.2.3 Power factor improving reactors 
The input power factor is improved to be about 90%. For use with a 1-phase power supply, it may be 
slightly lower than 90%. 
W
W1
C
RX S Y T Z
  5(
0.
2) 
D1
Installation screw
D   
5(0.
2)
 
[Unit : mm]
([Unit : in.])
3-phase 
200 to 230VAC
NFB
FR-BAL
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
1-phase 
230VAC
NFB
FR-BAL
R
S
T
X
Y
Z
L
1
L
2
L
3
MC
1-phase 
100 to120VAC
NFB
FR-BAL
R
S
T
X
Y
Z
L
1
L
2
MC
(Note)
Servo amplifier
MR-J2S-    CP
Servo amplifier
MR-J2S-    CP
Servo amplifier
MR-J2S-    CP
 
Note. Connect a 1-phase 230VAC power supply to L
1
/L
2
 and keep L
3
 open.