Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
6 -  9 
6. PARAMETERS 
 
6.1.11 Torque limit 
Parameter 
No. Symbol 
Name 
Initial 
value 
Unit Setting 
range 
PA11 
TLP 
Forward rotation torque limit 
100.0 
0 to 100.0 
PA12 
TLN 
Reverse rotation torque limit 
100.0 
0 to 100.0 
 
The torque generated by the servo motor can be limited. 
 
(1) Forward rotation torque limit (parameter No.PA11) 
Set this parameter on the assumption that the maximum torque is 100[%]. Set this parameter when limiting 
the torque of the servo motor in the CCW driving mode or CW regeneration mode. Set this parameter to 
"0.0" to generate no torque. 
 
(2) Reverse rotation torque limit (parameter No.PA12) 
Set this parameter on the assumption that the maximum torque is 100[%]. Set this parameter when limiting 
the torque of the servo motor in the CW driving mode or CCW regeneration mode. Set this parameter to 
"0.0" to generate no torque.