6. PARAMETERS 
 
6.1.12 Selection of servo motor rotation direction 
Parameter 
No. Symbol 
Name 
Initial 
value 
Unit Setting 
range 
PA14  *POL  Rotation direction selection 
 
0 1 
 
POINT 
 
This parameter is made valid when power is switched off, then on after 
setting. 
 
Select servo motor rotation direction relative to the input pulse train. 
 
Servo Motor Rotation Direction 
Parameter No.PA14 
Setting 
Forward rotation start (Ryn1) 
ON 
Reverse rotation start (Ryn2) 
ON 
0 CCW  CW 
1 CW  CCW 
 
Forward rotation (CCW)
Reverse rotation (CW)
 
6.1.13 Encoder output pulse 
Parameter 
No. Symbol 
Name 
Initial 
value 
Unit Setting 
range 
PA15  *ENR  Encoder output pulse 
4000 
pulse/ 
rev 
1 to 65535 
 
POINT 
 
This parameter is made valid when power is switched off, then on after 
setting. 
 
Used to set the encoder pulses (A-phase, B-phase) output by the servo amplifier. 
Set the value 4 times greater than the A-phase or B-phase pulses. 
You can use parameter No.PC19 to choose the output pulse setting or output division ratio setting. 
The number of A/B-phase pulses actually output is 1/4 times greater than the preset number of pulses. 