Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
14 -  19 
14. OPTIONS AND AUXILIARY EQUIPMENT 
 
14.2 Regenerative options 
CAUTION 
The specified combinations of regenerative options and servo amplifiers may only 
be used. Otherwise, a fire may occur. 
 
(1) Combination and regenerative power 
The power values in the table are resistor-generated powers and not rated powers. 
 
Regenerative power[W] 
Servo amplifier 
Built-in 
regenerative
resistor 
MR-RB032 
[40 ] 
MR-RB12 
[40 ] 
MR-RB30 
[13 ] 
MR-RB31 
[6.7 ] 
MR-RB32 
[40 ] 
(Note 1) 
MR-RB50 
[13 ] 
(Note 1) 
MR-MB51 
[6.7 ] 
MR-J3-10T 
(1) 
 30       
MR-J3-20T 
(1) 
10 
30 
100 
     
MR-J3-40T 
(1) 
10 
30 
100 
     
MR-J3-60T 
10 
30 
100 
     
MR-J3-70T 
20 30 100    300    
MR-J3-100T 
20 30 100    300    
MR-J3-200T 
100    300    500  
MR-J3-350T 
100    300    500  
MR-J3-500T 
130      300    500 
MR-J3-700T 
170      300    500 
 
 
 Regenerative 
power[W]  
 
Servo amplifier 
Built-in 
regenerative
resistor 
MR-RB1H-4 
[82 ] 
(Note 1) 
MR-RB3M-4
[120 ] 
(Note 1) 
MR-RB3G-4
[47 ] 
(Note 1) 
MR-RB5G-4
[47 ] 
(Note 1) 
MR-RB34-4 
[26 ] 
(Note 1) 
MR-RB54-4 
[26 ] 
MR-J3-60T4 15  100  300   
 
 
 
MR-J3-100T4 15  100  300 
 
 
 
 
MR-J3-200T4 100 
 
 
300  500 
 
 
MR-J3-350T4 100 
 
 
300  500 
 
 
MR-J3-500T4 
130 
    
300 
500 
MR-J3-700T4 
170 
    
300 
500 
 
(Note 2) Regenerative power[W] 
Servo amplifier 
External regenerative 
resistor (Accessory) 
MR-RB5E 
[6 ] 
MR-RB9P 
[4.5 ] 
MR-RB9F 
[3 ] 
MR-RB6B-4 
[20 ] 
MR-RB60-4 
[12.5 ] 
MR-RB6K-4 
[10 ] 
MR-J3-11KT 
500 (800) 
500 (800) 
 
 
 
 
 
MR-J3-15KT 
850 
(1300)  
850 
(1300) 
    
MR-J3-22KT 
850 
(1300)   
850 
(1300) 
   
MR-J3-11KT4 
500 
(800)    
500 
(800) 
  
MR-J3-15KT4 
850 
(1300)     
850 
(1300) 
 
MR-J3-22KT4 
850 
(1300)      
850 
(1300) 
Note 1. Always install a cooling fan. 
2. Values in parentheses assume the installation of a cooling fan.