Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
15 -  45 
15. COMMUNICATION FUNCTION 
 
15.5.12 Servo amplifier group designation 
With group setting made to the slave stations, data can be transmitted simultaneously to two or more slave 
stations set as a group. 
 
(1) Group setting write 
Write the group designation value to the slave station. 
(a) Transmission 
Transmit command [9][F], data No. [0][0] and data. 
Command Data 
No. 
Data 
[9][F] [0][0] 
See 
below. 
0
0
Group designation
0: No group designation
1: Group a
2: Group b
3: Group c
4: Group d
5: Group e
6: Group f
Response command enable
  Set whether data can be sent back or not in
  response to the read command of the master station.
  0: Response disable
        Data cannot be set back.
  1: Response enable
        Data can be set back.
 
 
(2) Group setting read 
Read the set group designation value from the slave station. 
(a) Transmission 
Transmit command [1][F] and data No. [0][0]. 
Command Data 
No. 
[1][F] [0][0] 
 
(b) Reply 
The slave station sends back the group setting of the point table requested. 
0
0
Group designation
0: No group designation
1: Group a
2: Group b
3: Group c
4: Group d
5: Group e
6: Group f
Response command enable
0: Response disable
1: Response enable