16. INDEXER POSITIONING OPERATION
 
16. INDEXER POSITIONING OPERATION 
POINT 
 
To execute the indexer positioning operation, parameter needs to be 
changed. Set the parameter No.PA01 to "1
". 
 
This chapter provides the indexer positioning operation method using MR-J3- T servo amplifier. Any matters 
not described in this chapter are the same as those of the point table positioning operation. For more 
information, refer to chapters up to 15. 
 
16.1 Function 
16.1.1 Overview 
Using the next station selection 1 (RYnA) to the next station selection 8 (RY(n 2)5) devices, stations from 
No.0 to No.254 can be specified. 
Settings of servo motor speed and acceleration/deceleration time constant are carried out by specifying the 
point table number from 1 to 8 using the speed selection 1 (RY(n 2)C) to the speed selection 3 (RY(n 2)E) 
devices. Speed command data can be directly specified by using the remote register when two stations are 
occupied. 
 
16.1.2 Servo amplifier standard specifications (functions only) 
  
Item 
 
Description 
Station command 
input 
Available with CC-Link communication 
CC-Link communication (1 station occupied): 31 stations 
CC-Link communication (2 stations occupied): 255 stations 
Remote 
register 
Available with CC-Link communication (2 stations occupied) 
Set the speed command data (speed) by the remote register. 
Command 
system  
Speed 
command 
input 
Speed 
No. input 
Select a speed and acceleration/deceleration time constant by the point table 
Rotation direction 
specifying indexer 
Positioning operation is executed to the set station. Rotation direction can be specified. 
Automatic 
operation 
mode 
Shortest rotating 
indexer 
Positioning operation is executed to the set station. The servo motor rotates in the closest 
direction from current position. 
Indexer JOG 
operation 
Turning on the start signal (RYn1) makes the servo motor rotate in the direction specified by 
the rotation direction specifying. 
Turning off the start signal (RYn1) makes the servo motor perform positioning operation to the 
closest station where the motor can decelerate to stop. 
Manual 
operation 
mode 
JOG operation 
In accordance with the speed data set in parameters, JOG operation is performed by using 
CC-Link communication 
Torque limit 
changing dog type 
Home position return is performed by the Z-phase pulse count after passing proximity dog. 
Home position address may be set. Home position shift distance may be set. Home position 
return direction may be selected. 
Automatic at-dog home position return return/automatic stroke return function. 
Automatic torque limit changing function 
Home 
position 
return 
mode 
Torque limit 
changing data 
setting type 
Home position return is made without dog. 
Home position may be set at any position by manual operation, etc. Home position address may 
be set. 
Automatic torque limit changing function 
Operat
ion m
ode 
Automatic positioning to home 
position 
High-speed automatic return to a defined home position.