Using a RS-485 communication, it will be able to control the OSD menu at the 
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera 
and serial cable 
EX)  SERIAL PORT OF THE PC(COM1) → SERIAL CABLE  → RS-485 CONVERTER → RS-485 
CONTROL CABLE
(2)The case which it controls from the DVR or System Controller 
It connects the RS-485 control cable in the connection terminal of 485 control 
boards which are connected with the DVR or System Controller.
Connecting to RS-485 Control Cable
• When you construct external control systems for a camera control, please use to the SAMSUNG
TECHWIN PROTOCOL or PELCO-D PROTOCOL.
• When you connecting to RS-485 control cable, please peel off the outer skin inside the RS-485
control cable.
• In case of SCC-101 connection, change communication mode to 『8-E-1』 at 『Communication
configuration』menu. (For more information, refer to SCC-101 manual.)
Notes
* RS-485 Communication establishment initial value
Connection
 485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL
RED (TRX+)
(-) CONNECTION TERMINAL
WHITE (TRX-)
CONTROL CABLE
SPEC
RED    (TRX+)
RS-485+
WHITE(TRX-)
RS-485-
Item
Camera ID
BAUD RATE
UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
Setup Menu
LENS
●DC
EXPOSURE
●SHUTTER…
●AGC…………………
● SENS-UP………
● RETURN…
WHITE BALANCE
● ATW…
●MANUAL…
●AWC→SET…
●OUTDOOR…
● INDOOR
BACKLIGHT
 OFF
WDR                   
 BLC
 HLC
SSNR
 ON
 OFF
DAY/NIGHT
 COLOR
B/W
AUTO
IMAGE ADJUSTMENT
(IMAGE ADJ.)
FREEZE
V-REV
………
 H-REV
D-ZOOM
SHARPNESS
………… ●
 RETURN
SPECIAL
CAMTITLE
SYNC
………
MOTION DET 
PRIVACY
DIS
……
COMM ADJ
LANGUAGE
RESET
RETURN
EXIT
Operating Your Camera
Use the Function Setup switch on back of the camera.
Function Setup switch
RS-485 communication control
Menu Setup
Menu Configuration