Lucent Technologies Release 7 ユーザーズマニュアル

ページ / 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1312
POWER 
9
POWER
Battery and Charger for AC-Powered Systems
DEFINITY Systems support two different cabinet types: multicarrier and single 
carrier. Single carrier cabinets are used only for EPNs. Both cabinet types may 
be powered by either AC or DC external power source. Environmental 
maintenance differs according to cabinet type and external power supply. 
AC-powered Multi-Carrier Cabinets can be equipped with rechargeable batteries 
that provide backup power during short power outages. Battery backup is 
optional on cabinets powered by an Uninterruptible Power Supply (UPS), and is 
required on those that are not. DC-powered cabinets and single-carrier cabinets 
do not have battery backup, and this MO is not valid for those cabinets.
The battery backup for the J58890CH unit consists of one battery assembly and 
charger. The battery backup for the J58890CE unit consists of three 48V 
batteries and a battery charger. Each cabinet so equipped has its own 
independent battery backup unit. When power to the cabinet is interrupted, a 
warning alarm is logged against AC-POWER and the system draws power from 
the backup batteries. This is known as Nominal Power Holdover (NPH). If power 
is restored before the NPH time expires, the alarm is resolved. If power does not 
return, error logs are saved to the Mass Storage System. The nominal power 
holdover provided is as follows:
When AC power is restored after an outage, the battery charger fully recharges 
the batteries within 30 hours.
In a multi-carrier cabinet system, the Battery & Battery Charger maintenance 
object represents the battery charger and the battery which are located in the 
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
1.
UU is the cabinet number indicated in the PORT field from the Alarm or Error Log.
Full Name of MO
POWER
MINOR
test environment 
UU 
Battery and Battery Charger
PPN Cabinet:
All carriers
10 seconds
Simplex control carrier
10 minutes
Duplicated control carriers
5 minutes
EPN cabinet:
All carriers
15 seconds
Expansion control carrier
10 minutes