Lucent Technologies Release 6 ユーザーズマニュアル

ページ / 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Test the System 
Page 4-13
LED Indicators 
4
LED Indicators
Refer to 
DEFINITY Enterprise Communications Server Release 6 Maintenance for 
R6r
 for detailed alarm and LED descriptions. If a maintenance object begins to 
fail some periodic tests, the system generates an alarm. The system identifies 3 
levels of alarms:
Major Alarms 
 Failures that cause critical degradation of service and 
require immediate attention.
Minor Alarms 
 Failures that cause some degradation of service, but do 
not cause a critical portion of the system to be inoperable. This condition 
requires action, but its consequences are not immediate. Problems might 
be impaired service to a few trunks or stations or interfering with one 
feature across the entire system.
Warning Alarms 
 Failures that cause no significant degradation of 
service or failures in equipment external to the system. Warning alarms 
are not reported to the attendant console or INADS.
Alarms are communicated to the system users and technicians by entries in the 
alarm log and the lighting of LEDs located on the attendant console, on all circuit 
packs, and, optionally, on customer-designated voice terminals.
Attendant Console LEDs
The console has 2 red LEDs, labeled “ALM” and “ACK”. The ALM LED lights 
steadily when there is a major or minor alarm at the system cabinet. The ACK 
LED lights steadily if the alarm has been successfully reported to INADS. If the 
system is unable to report the alarm to INADS, the LED flashes; this signals the 
attendant to call INADS and report the alarm.
Terminal Alarm Notification
Terminal Alarm Notification is an optional feature that displays several types of 
alarms on voice terminals with administered feature buttons or the attendant 
console. A maximum of 10 digital and/or hybrid voice terminals may be used.
When an alarm occurs, the green status LED associated with the assigned 
button is in a steady state. The LED may be turned off by pressing the button 
associated with the LED. If the LED is off and the alarm has not been resolved by 
the time maintenance reschedules testing, the green status LED resumes its 
steady state.