Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-115
Add Packet Bus to R6si 
5
High or Critical Reliability R6si System
Disable Alarm Origination
1. Enter change system-parameters maintenance and press 
Enter
2. Set the 
Alarm Origination Activated
 field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets. 
3. For some releases of software, disable 
Cleared Alarm Notification
 
and 
Restart Notification
 before submitting the form.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter
 to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter.
 This instructs the system to write 
all translation information to the translation card or the tape.
Power Down the Control Carrier 
NOTE:
For a high or critical reliability system, do not power down both control 
carriers at the same time. This defeats the duplication feature of the system.
1. Power down the control carrier and install the appropriate circuit packs. 
See 
Table 5-22
.
1.
Quantity of this pack should equal the number of EPNs.
2.
Required for critical reliability PPN. Optional for digital trunk testing in high reliability 
PPN.
Table 5-22.
Circuit Pack Locations for Packet Bus in PPN
Circuit Pack
Carrier
Quantity
Slot
TN778
Control Carrier A
2
PACKET CONT
Control Carrier B
2
PACKET CONT
TN570
Control Carrier A
1 or 2
1
EXPN INTFC/1 and /2
Control Carrier B
1 or 2
EXPN INTFC/1 and /2
TN771C
Control Carrier A
1
2
Any Available Port Slot