DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-116
Add Packet Bus to R6si 
5
.
Power Up System
1. Power up the system.
2. Enter change system-parameters maintenance and press 
Enter
. Use this 
form to enable the packet bus.
3. Perform tests.
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance for R6r
Contact INADS to Enable Customer Options and
Verify Alarm Origination
Be sure the system is part of the existing INADS database by calling the INADS 
Database Administrator at the Technical Service Center (TSC). Verify that INADS 
can dial into the system and that the system can dial out to INADS. 
As part of the system registration process, the INADS Database Administrator 
enables Alarm Origination and enables customer options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has purchased a 
services contract, the system cannot report any alarm to the TSC 
automatically, causing the TSC to be unable to fulfill the services contract.
1.
Quantity of this pack should equal the number of EPNs.
2.
Required for critical reliability EPN. Optional for digital trunk testing in high reliability 
EPN.
Table 5-23.
Circuit-Pack Locations for Packet Bus in Each EPN
Circuit Pack
Carrier
Quantity
Slot
TN570
Expansion Control 
Carrier A
1 or 2
1
EXPN INTFC/01 and /02
Port Carrier B
1 or 2
EXPN INTFC/02 and /03
TN771C
Expansion Control 
Carrier A
1
2
Any Available Port Slot