Mitsubishi Electronics MDS-D-SPJ3 ユーザーズマニュアル

ページ / 284
3 - 19
MDS-D-SVJ3/SPJ3 Series Specifications Manual
3-5 Sequence functions
3-5-4 Specified speed output
This function is to output a signal that indicates whether the machine-end speed has exceeded the speed 
specified with the parameter.
With this function, the protection door, etc. can be locked to secure the machine operator when the machine-
end speed has exceeded the specified speed. This function can also be used for judging whether the current 
machine-end speed is higher than the specified speed.
3-5-5 Quick READY ON sequence
With this function, the charging time during READY ON is shortened according to the remaining charge 
capacity of the power supply unit. When returning to READY ON status immediately after the emergency 
stop input, the charging time can be shortened according to the remaining charge capacity and the time to 
READY ON is shortened.