Mitsubishi Electronics MDS-D-SPJ3 ユーザーズマニュアル

ページ / 284
3 - 20
3 Function Specifications
MITSUBISHI CNC
3-6 Diagnosis function
3-6-1 Monitor output function
<Servo drive unit>
Drive unit has a function to D/A output the various control data. The servo adjustment data required for 
setting the servo parameters to match the machine can be D/A output. Measure using a high-speed 
waveform recorder, oscilloscope, etc.
(1) D/A output specifications
When the output data is 0, the offset voltage is 2.5V. If there is an offset voltage, adjust the zero level 
position in the measuring instrument side.
Item
Explanation
No. of channels
2ch
Output cycle
0.8ms (min. value)
Output precision
10bit
Output voltage range
0V to 2.5V (zero) to +5V
Output magnification setting
-32768 to 32767 (1/100-fold)
Output pin (CN9 connector)
MO1 = Pin 4,   MO2 = Pin 14, LG = Pin 1,11
 
 
MO1
LG 
 
 
 
 
 
 
 
10 

CN9
 
19 
MO2
LG
 
 
 
 
 
12 
 
 
15 
11 
16 
14 
13 
20 
17 
18 
MDS-D-SVJ3
connector
Pin
Name
Pin
Name
+2.5 [V]
0 [V]
Speed FB  
Current FB
+2.5 [V]
0 [V]
+5 [V]
+5 [V]
Example of D/A output waveform