Extron electronic DTPTEU232 ユーザーズマニュアル

ページ / 40
 
DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Installation and Operation
17
 
Operation
The DTP T EU and DTP T MK units can be controlled only by SIS commands (see 
 on page 19) or the Product Configuration Software (see 
operation details. Topics in this section include:
Indications 
PWR HDCP HDMI VGA AUTO
• 
Power LED — Lights when power is applied.
• 
HDCP LED — Lights when the HDMI input signal is encrypted.
• 
HDMI LED — Lights when an HDMI input signal is detected.
• 
VGA LED — Lights when a VGA input signal is detected.
• 
Auto LED — Lights when the device is in auto switch mode.
Switch Modes
The switching transmitter has three switch modes:
• 
Manual — The input must be selected manually using an SIS command
• 
Auto switch (VGA) — The switcher automatically selects the input with an active signal 
present and, if both are present, prioritizes the VGA input. 
This is the factory default 
mode.
• 
Auto switch (HDMI) — The switcher automatically selects the input with an active 
signal present and, if both are present, prioritizes the HDMI input.
These modes can be selected through SIS commands (see 
on page 22) or the Product Configuration Software (see the PCS Help file)
.
EDID
commands on page 23) or the Product Configuration Software (see the PCS Help file). The 
DTP T EU and DTP T MK units can record and save EDID in a user memory location, select 
a pre-defined EDID, or use EDID from a display connected to a receiver. EDID stored in the 
user memory location can come from the display connected to a receiver or a custom EDID 
imported through the Product Software.
Reset
Use the recessed Reset button on the side of the transmitter (see 
 on page 7 and 
 on page 8) to initiate a reset to the default settings. Press and 
hold the reset button 
for approximately 6 seconds. All front panel LEDs cycle. Release the button. This reset is the 
equivalent of issuing the 
 SIS command (
E
ZXXX
}
, see page 25).