Preface
1.4
Notational conventions
The following notational conventions are used in this manual:
1.5
Technical data
Electrical data (hot-plug power supply unit)
Text in italics
indicates commands or menu items.
"Quotation marks"
indicate names of chapters and terms that are being 
emphasized.
Ê
describes activities that must be performed in the order 
shown.
V
CAUTION!
pay particular attention to texts marked with this symbol. 
Failure to observe this warning may endanger your life, 
destroy the system or lead to the loss of data.
I
indicates additional information, notes and tips.
Rated voltage range
100 - 127 V / 200 - 240 V
Frequency 
50 Hz - 60 Hz
Rated current (basic configuration)
3.1 A (240 V)
Max. rated current
11 A (240 V)
Active power min. (typical configuration)
750 W
Active power max. (typical configuration) 1800 W
Rated active power max. 
2640 W (11 A x 240 V)
Apparent power (typical configuration)
1830 VA
Heat dissipation
750 W/h =  2559 btu/h
1950 W/h =  6654 btu/h
3360 W/h = 11465 btu/h
Main power fuse
16 A
Protection class
I