Fujitsu RX600 S6 ユーザーズマニュアル
24
Operating Manual
RX600
S6
Preface
Dimensions / Weight
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Rack (W x D x H)
482.6 mm (Bezel) / 444.8 mm (Body) x 765.0 mm x
176.0 mm
176.0 mm
Mounting depth rack
728 mm
Height unit rack
4 U
19" rackmount
Yes
Mounting cable depth
rack
rack
100 mm (1000 mm rack recommended)
Weight
minimum 32 kg; maximum 46 kg (actual weight may
vary depending on configuration)
vary depending on configuration)
Rack integration kit
rack integration kit as option
Environment class 3K2
Environment class 2K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
10°C - 35°C
Transport (2K2)
-25°C - 60°C
Humidity
10% - 85% (non condensing)
Sound power level L
WAd
(ISO 9296)
< 6.5 B (standby)
< 6.6 B (operation)
< 6.6 B (operation)
Sound pressure level at bystander position L
pAm
(ISO 9296) (at < 23 °C)
< 50 dB(A) (standby)
< 50 dB(A) (operation)
< 50 dB(A) (operation)