Electrical
WIRING COLOR CODE
C o l o r D e s c r i p t i o n
D e s c r i p c i o n
D e s c r i p c i o n
G RO U N D
T I E R R A   M A S A
M A S S E
A N T I - S W E AT
A N T I C O N D E N S C I O N
A N T I - S U I N T E M E N T
L I G H T S
L U C E S
E C L A I R A G E
R E C E P TA C L E S
E N C H U F E R
R E C E P TA C L E
T- S TAT / S O L E N O I D   230 V THERMOSTATO / SOLENOID (230 VAC)
SOUPAPE A SOLENOID (230 V)
T- S TAT / S O L E N O I D   115 V THERMOSTATO / SOLENOID (115 VAC)
SOUPAPE A SOLENOID (115 V)
FAN MOTORS
VENTILADORES
VENTILATEUR
S TA N DA R D   C A S E   W I R E   C O L O R   C O D E
C O D I G O   D E   C O L O R E S   D E   L O S  A L A M B R E S   PA R A   L A S  V I T R I N A S   E S TA N DA R
C O D E   C O U L E U R   P O U R   F I L S   D E   B O I T I E R   N O R M A L I S E
4 3 0 - 0 1 - 0 3 3 8   r 9 9 0 8
CASE MUST BE GROUNDED
NOTE: Refer to label illustrated above that is affixed to case to
determine the actual configuration as checked in the “TYPE
INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length fluores-
cent lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
ELECTRICAL SERVICE RECEPTACLES
(WHEN APPLICABLE)
The receptacle that is provided on the exterior back of
these models is intended for computerized scales with a
fifteen amp maximum load, not for large motors or other
high wattage appliances. It should be wired to a dedicated
circuit.
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heat-
ers, Thermostats, and Lights.
FIELD WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration
control panel to the merchandisers is required for re-
frigeration thermostats. Most component amperes are
listed in the “Case Specs” section, but always check the
serial plate.
BALLAST LOCATION
Ballasts are located within the access panel that runs
the length of the rear of the case. Refer to diagram on
page 6.
WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes
stamped on the serial plate.  Actual ampere draw may be
less than specified. Field wiring from the refrigeration con
trol panel to the merchandisers is required for refrigera-
tion thermostats.  Most component amperes are listed in
the "Case Specs" section, but always check the serial plate.
ASHRAE COLOR CODE
NOTE: All other manufacturers have no standard sensor codes.
Case Control Systems
SENSOR COLOR
Manufacturer ® >
EIL
CP
Location
Coil Inlet
Color
Blue
Blue
Part#
225-01-1755
225-01-3255
Coil Outlet
Color
Red
Red
Part#
225-01-1757
225-01-3123
Discharge Air
Color
Green
Green
Part#
225-01-1756
225-01-3260
Return Air
Color
Purple
Green
Part#
225-01-1758
225-01-3260
Defrost Term.
Color
White
Orange
Part#
225-01-0650
225-01-3254
Liquid Line
Color
White
Blue
Part#
225-01-0650
225-01-3255