Installer Instructions 
 
7
 
 
 
2.2  Room ventilation 
 
   
 
 The appliance may only be installed in constantly ventilated rooms, in accordance with the 
regulations in force. The room where the appliance is installed must provide sufficient air for frequent 
gas combustion and the renewal of the air in the room. The air intakes, which are protected by grates, 
must be of a suitable size (in accordance with the regulations in force) and be placed where they 
cannot be obstructed either wholly or partially. The openings must enable 2 m
3
/h of air to enter per 
kW of gas power of the appliance. 
The kitchen must be suitably ventilated in order to eliminate the heat and humidity produced by 
cooking. In particular, after extended use, you are advised to open a window or step up the speed of 
any fans in use. 
 
   
 
 
2.3  Discharge of combustion products 
 
   
 
  Combustion products must be discharged by means of a hood connected to a reliable naturally 
drawing chimney or one using forced suction. An effective suction system must be carefully designed 
by a specialist, respecting the positions and distances set out in the relevant regulation. When the 
installation is complete, the installer must provide a certificate of conformity. 
 
   
 
 
2.4  Connecting up the gas using a flexible hose 
 
   
 
  ATTENTION: Please observe the requirements set out in the paragraph marked "Important". 
 
 
 
 
 
 
 
Important. 
The appliance must be installed and maintained by a qualified professional in accordance with the 
regulations in force and good professional practice, in particular: 
• 
Order of 2 August 1977 
Technical and Safety Regulations applicable to installations using combustible gas and liquid 
hydrocarbons inside residential buildings and structures connected thereto. 
• 
Standard DTU P 45-204 
Gas installations (formerly DTU No 61-1 - Gas Installations, April 1982 + Supplement No 1, July 
1984). 
• 
Local Health Regulation 
For appliances connected to the electricity network. 
• 
Standard NF C 15-100 
Low-voltage electrical installations - Rules. 
 
   
 
 
IN ACCORDANCE WITH THE REGULATIONS IN FORCE, THE APPLIANCE CAN ONLY BE 
CONNECTED UP WITH RUBBER HOSES IF THE FULL LENGTH OF THE HOSE CAN BE 
INSPECTED. 
 
   
 
  2.4.1
  Natural gas connection 
 
 
 
 
  If you have an old installation, you can use a flexible hose in accordance with 
Standard NFD36-102. 
Screw hose-end fitting A onto the end of pipe B of the appliance, interposing seal 
C between the two, carefully thread on flexible hose D and fix the hose to hose-
end fitting A using safety collar E. The flexible hose may only be used if the 
appliance has been installed in isolation from the network.