Multi-Tech Systems MVP-2410 ユーザーズマニュアル

ページ / 395
MultiVOIP User Guide  
Technical Configuration 
 
97
 
T1 Parameter Definitions (cont’d) 
 
Field Name 
Values 
Description 
General T1/E1/ISDN Parameters 
 
Line Build Out  0 dB,  -7.5 dB,  
-15 dB, -22.5 dB 
To reduce the crosstalk on 
received signals, a transmit 
attenuator can be placed in the 
data path.  Transmit attenuation 
is selectable.  Default: O dB 
Pulse Shape 
Level 
0 to 40 Meters 
40 to 81 m 
81 to 122 m 
122 to 162 m 
162 to 200 m 
Refers to length of cable 
between MultiVOIP and 
PBX/telco in meters. Most 
common will be 0 to 40m.
 
Caller ID Parameters
 
 
Caller ID 
Enable 
Y/N 
Turns Caller ID feature on (if 
checked) and off (if unchecked). 
Calling 
Number Prefix 
(Caller ID) 
0-9, *, # 
A DTMF symbol used to mark the 
beginning of the calling party 
number for use with Caller ID. 
Maximum length:  4 characters. 
Calling 
Number Suffix 
(Caller ID) 
0-9, *, # 
A DTMF symbol used to mark 
the end of the calling party 
number for use with Caller ID. 
Maximum length:  4 characters.
 
Detect Flash 
Hook 
Y/N 
This setting determines whether 
or not the MultiVOIP responds 
to hook-flash signals. 
Detection Time  100 – 1500 
milliseconds 
Minimum hook-flash time that 
will be interpreted as a valid 
flash by the MultiVOIP. 
Generation 
Time  
100 – 1500 
milliseconds 
In some systems, a MultiVOIP 
might receive a hook-flash signal 
from an upstream device (a PBX, 
voip or other device) and must 
replicate it to a downstream device.  
This parameter determines the 
duration of the hook-flash signal 
that is passed to a downstream 
device. 
Clocking External/Internal
Set opposite to telco/PBX setting.  
Example: if telco clocking internal, 
set VOIP clocking as external.